UI Builder pivot table with multiple data sources displays "No data available" when the data point limit is exceededIssue A pivot table visualization on a UI Builder page, such as a workspace page, displays “No data available” even though the underlying data sources contain records. The condition is most noticeable on pivot tables that draw from several data sources, while other pivot tables on the same experience that use a single data source render correctly. Symptoms A pivot table on a UI Builder or workspace page shows the generic “No data available” empty state.The pivot table is configured with multiple data sources, and the same data sources return data when used individually.Pivot tables built on a single one of those data sources display correctly on other pages.The final grouped and summarized table would be small if it rendered, so the empty result does not match the expected output.Reports or lists built directly on the same tables confirm that records exist.No error message is shown to the user, and no obvious error appears on the page. Release You can expect to see this issue in Zurich. Along with specific configurations listed below: Zurich release family, and potentially earlier releases that include the same pivot table visualization component, until the fix is delivered.Fixed in the Brazil release family (November 2026), per the current target.Pivot table visualizations on UI Builder pages, including workspace pages, that use more than one data source.Configurations with large source tables, many columns returned per data source, or broad or unfiltered data source conditions, which make exceeding the data point limit more likely. Cause Pivot table visualizations enforce an internal limit on the number of data points a configuration can process. The limit is controlled by the system property par_viz.table_data.max_data_points. It is evaluated against the underlying data pulled from the configured data sources, before the data is grouped and summarized, and not against the number of cells the finished table displays. When a pivot table uses multiple data sources, the limit is assessed against the combined volume of all of them. A configuration can therefore exceed the limit even when each individual data source stays under it. When the limit is exceeded, the visualization returns no records. The condition is misleading because the specific limit error is not surfaced by the visualization component on a workspace page. The component falls back to the generic “No data available” empty state instead. This is a known defect tracked under PRB2000611, and the masked error message has been raised separately. Resolution Two options are available to restore the data. Option 1 (recommended): Refine the conditions on each data source feeding the pivot table so that each one returns fewer rows and columns. Any filter that narrows the source query reduces the data point count, for example a date boundary, a category restriction, or a status condition. Steps: Open the page in UI Builder and select the pivot table component.Review each data source configured for the component.Add or tighten conditions on each data source to reduce the volume of records and fields returned.Save the changes and reload the page to confirm the pivot table renders.This option is the durable one because it continues to work as the underlying data grows. Option 2 (short-term measure): Increase the value of the system property par_viz.table_data.max_data_points. Steps: Navigate to sys_properties.list.Locate the property par_viz.table_data.max_data_points.Increase the value to a level that allows the pivot table configuration to load.Reload the page and confirm the pivot table renders.Be aware that the limit exists to protect instance performance. Raising it can introduce performance issues on dashboards and pages that use these visualizations. If the data volume is expected to grow, a higher limit only defers the problem. This option is best used alongside the source refinement in Option 1 and not as a standalone fix. Permanent fix: A permanent fix for PRB2000611 is targeted for the Brazil release family. No backport to Zurich is currently planned.