Serial number not populated on discovered Infoblox devices Issue ProblemSerial numbers for Infoblox appliances are not being populated in the cmdb_serial_number table despite being visible in the Discovery payload after configuring the SNMP probe to retrieve the serial number using the OID The devices are classified and discovered successfully, but the serial number data is not processed into the serial number table or in the serial number field of the CI Release Discovery and Service Mapping Patterns - Any release Cause Root CauseThe out-of-box Network Switch pattern does not include logic to process the Infoblox-specific SNMP OID for serial numbers, resulting in the serial number data not being inserted into the cmdb_serial_number table Resolution Steps to ResolveAdd an extra step in the Network Switch pattern to capture the Serial Number OID for Infoblox devices, as the out-of-box pattern does not include logic to handle this specific OID. To request inclusion of this functionality in future out-of-box releases, raise a voice in the Idea Portal at https://support.servicenow.com/ideas