Intune Service Graph Connector – mandatory operational_status error during transform Issue ProblemWhen configuring the Service Graph Connector for Microsoft Intune, the SG-Intune Computer import job was failing for most records during the transform phase. The error 'Missing mandatory field(s) [operational_status] in table [cmdb_ci_network_adapter]'. Release N/A Cause Root CauseThe operational_status field was set as mandatory on the parent cmdb_ci table, but the out-of-the-box (OOB) Service Graph Connector for Intune does not populate this field for the network adapter class (cmdb_ci_network_adapter), leading to Identification and Reconciliation Engine (IRE) errors. Note: OOTB the cmdb_ci table does not have it's operational_status set to mandatory Resolution Steps to Resolve1. Modify the dictionary entry for the operational_status column on the cmdb_ci table.2. Uncheck the 'Mandatory' setting for the operational_status field in the dictionary.3. Reprocess and transform the import set again to ensure the changes take effect.