Smart Assessment notification not triggered for Control Attestation (sn_compliance_control)Issue When a Smart Assessment is created through the Control Attestation flow (via the Attest UI action on a Control record), the OOB"Notify Smart assessment creation" notification is not triggered, even though the assessment record is created successfully. The event this notification relies on, sn_risk_advanced.smart_asmt_creation, is only queued for assessments scoped to sn_grc_profile with a matching Risk Identification record — Control Attestation assessments are scoped to sn_compliance_control and do not meet this condition, so the event never fires. Symptoms The"Notify Smart assessment creation" out-of-the-box (OOB) notification does not fire when an assessment is created through the Control Attestation flow.Clicking the Attest UI action on a Control record successfully creates a Smart Assessment instance, but no notification is sent to the configured attestation respondents.The notification event, scripts, and notification record all exist and are active in the instance.No business rules, flows, or other trigger mechanisms responsible for firing the event can be found.The behaviour is reproducible in lower (non-production) environments. Release All Cause The notification is driven by the event sn_risk_advanced.smart_asmt_creation, which is queued from the OOB Script Include RiskIdentificationUtilsBase, inside the method _postProcessRIForSmartAsmt(). This method only queues the event when: a Smart Assessment is created against a sn_grc_profile scope item, anda matching Risk Identification record exists in new state for the same profile. When both conditions are met, the Risk Identification record moves to Information Gathering, smart_assessment_generated is set to true, and the event fires. Assessments created through the Control Attestation flow (via the Attest UI action) are scoped to the sn_compliance_control table, not sn_grc_profile. Because the scope item is not sn_grc_profile, the OOB logic exits before queuing the event, and the notification is never triggered. This is confirmed intentional, by-design behaviour, not a defect. The event registration, Script Include logic, and template category filtering are all scoped specifically to the Risk Identification process under Advanced Risk. Control Attestation relies on separate events, such as sn_smart_asmt.asmt_group_opened and sn_smart_asmt.asmt_group_closed, for its own process. Resolution There is no fix to apply, since the behaviour is by design. If a similar notification is required for Control Attestation, consider one of the following: Configure a new event and business rule specifically for Smart Assessments scoped to sn_compliance_control.Monitor the generic sn_smart_asmt.asmt_inst_opened event and add custom filtering for Control Attestation cases.If extending event coverage, review and update notification scripts to ensure correct data handling.If the goal is to unify event handling across both Risk Identification and Control Attestation flows, a code change is required to broaden the event's scope; otherwise, use separate events per module as per current design. As an interim measure, a more generic notification tied to the sn_smart_asmt_m2m_instance_persona table can serve the same purpose, since it is not restricted to the sn_grc_profile scope and fires for Control Attestation assessments.