Application node not upgraded to the correct version after an instance upgrade (node version mismatch)Issue In Very Rare Exceptions - After an instance upgrade, one or more application nodes may keep running the previous build while the rest of the instance runs the upgraded build. This causes inconsistent behavior depending on which node serves a request or runs a job. Symptoms - Flows or workflows fail intermittently, only for work that runs on one node. - Requests or approvals stay stuck (for example, requested items in Waiting for Approval). - Timer based or scheduled jobs are not processed as expected. - Pages or UI elements behave inconsistently from one session to another. - The issue can appear days after the upgrade, not only right after it. Facts - Production instances run on multiple application nodes, and all nodes should run the same build after an upgrade. - The upgrade process confirms completion at the database and instance level. It does not verify the version of each individual node.- A node that was out of the cluster or marked offline during the upgrade can miss the upgrade without an alert. - Customers cannot verify the build on each node themselves. Release All supported releases. This is related to the upgrade process and not to a specific release. Cause The post upgrade check validates the instance level version and does not validate each application node. A node that missed the upgrade keeps running the older build, which can conflict with the upgraded instance. Resolution 1. Open a case with ServiceNow Support (use P1 if production is impacted). Share the instance name, the upgrade change number, and when the symptoms started. 2. ServiceNow compares the build on each node. 3. The affected node is restarted through a change so it comes up on the correct build. This is planned with you because it can briefly affect running jobs. 4. Support confirms all nodes are on the same version. 5. If needed, Support recovers impacted records (stuck flows and requests) with validated scripts, run in production only with your approval. Long term improvements (status as of October 2026, no committed dates): - Node upgrade monitor reporting nodes upgraded vs total nodes with a status of In Progress, Complete or Failed. Recommendation: after every upgrade, watch for the symptoms above for the first few days. If you see them, open a case early and mention the upgrade change number. Related Links Known issue: PRB1761533