Configuration Error Opening Recommended Actions Panel in Risk Workspace - Risk EventsIssue When opening a Risk event record in Risk Workspace and attempting to view the Recommended Actions panel, the following error message appears: A configuration error has occurred. Contact your system administrator. Reproduced Steps Navigate to Risk Workspace.Open a Risk event record from the sn_risk_advanced_event table.Click on or open the Recommended Actions panel.The error message displays: A configuration error has occurred. Contact your system administrator. Release As of GRC: Predictive Intelligence - 22.3.1 Cause The Recommended Actions feature in Risk Workspace leverages Predictive Intelligence and relies on a Similarity Definition called Similarity Solution Definition for Risk Events (sys_id: eec45acd53520110bad1ddeeff7b12c3). This Similarity Definition should be active had this has active ML Solution that has been trained on current data. Resolution Verify and regenerate the ML Solution associated with the Similarity Definition by following these steps: Navigate to Predictive Intelligence -> Similarity -> Solution DefinitionSearch the Similarity Definition record for Risk Events (sys_id: eec45acd53520110bad1ddeeff7b12c3).Locate the associated ML Solution in the Similarity Definition configuration.Confirm the ML Solution is active and has a recent training date.If the ML Solution is inactive, click Update & Retrain to regenerate the solution based on current Risk event data.Allow the retraining process to complete (this may take several minutes depending on data volume).Confirme the Similarity Definition record for Risk Events is activeReturn to the Risk Workspace and verify that the Recommended Actions panel now loads without errors.