Multiple Assets on Purchase Order Line Receive Incorrectly Reference Same Asset IDIssue <!-- /*NS Branding Styles*/ --> .ns-kb-css-body-editor-container { p { font-size: 12pt; font-family: Lato; color: var(--now-color--text-primary, #000000); } span { font-size: 12pt; font-family: Lato; color: var(--now-color--text-primary, #000000); } h2 { font-size: 24pt; font-family: Lato; color: var(--now-color--text-primary, black); } h3 { font-size: 18pt; font-family: Lato; color: var(--now-color--text-primary, black); } h4 { font-size: 14pt; font-family: Lato; color: var(--now-color--text-primary, black); } a { font-size: 12pt; font-family: Lato; color: var(--now-color--link-primary, #00718F); } a:hover { font-size: 12pt; color: var(--now-color--link-primary, #024F69); } a:target { font-size: 12pt; color: var(--now-color--link-primary, #032D42); } a:visited { font-size: 12pt; color: var(--now-color--link-primary, #00718f); } ul { font-size: 12pt; font-family: Lato; } li { font-size: 12pt; font-family: Lato; } img { display: ; max-width: ; width: ; height: ; } } When receiving multiple distinct assets from a single Purchase Order Line (POL) through the import asset template in Hardware Asset Management, all staging rows are incorrectly stamped with the same asset ID after the receive operation completes. This breaks the association between staging records and their corresponding asset records. Symptoms<!-- /*NS Branding Styles*/ --> .ns-kb-css-body-editor-container { p { font-size: 12pt; font-family: Lato; color: var(--now-color--text-primary, #000000); } span { font-size: 12pt; font-family: Lato; color: var(--now-color--text-primary, #000000); } h2 { font-size: 24pt; font-family: Lato; color: var(--now-color--text-primary, black); } h3 { font-size: 18pt; font-family: Lato; color: var(--now-color--text-primary, black); } h4 { font-size: 14pt; font-family: Lato; color: var(--now-color--text-primary, black); } a { font-size: 12pt; font-family: Lato; color: var(--now-color--link-primary, #00718F); } a:hover { font-size: 12pt; color: var(--now-color--link-primary, #024F69); } a:target { font-size: 12pt; color: var(--now-color--link-primary, #032D42); } a:visited { font-size: 12pt; color: var(--now-color--link-primary, #00718f); } ul { font-size: 12pt; font-family: Lato; } li { font-size: 12pt; font-family: Lato; } img { display: ; max-width: ; width: ; height: ; } } After receiving multiple assets (with distinct serial numbers or asset tags) from the same PO line, inspection of the staging records shows all rows point to the same asset_id valueThe asset_id typically references only the first asset created for that PO line, not the distinct assets for subsequent rowsDownstream receive logic cannot correctly identify which physical asset corresponds to each staging rowWhen re-receiving existing assets, the system may move the wrong physical asset into the stockroom Facts<!-- /*NS Branding Styles*/ --> .ns-kb-css-body-editor-container { p { font-size: 12pt; font-family: Lato; color: var(--now-color--text-primary, #000000); } span { font-size: 12pt; font-family: Lato; color: var(--now-color--text-primary, #000000); } h2 { font-size: 24pt; font-family: Lato; color: var(--now-color--text-primary, black); } h3 { font-size: 18pt; font-family: Lato; color: var(--now-color--text-primary, black); } h4 { font-size: 14pt; font-family: Lato; color: var(--now-color--text-primary, black); } a { font-size: 12pt; font-family: Lato; color: var(--now-color--link-primary, #00718F); } a:hover { font-size: 12pt; color: var(--now-color--link-primary, #024F69); } a:target { font-size: 12pt; color: var(--now-color--link-primary, #032D42); } a:visited { font-size: 12pt; color: var(--now-color--link-primary, #00718f); } ul { font-size: 12pt; font-family: Lato; } li { font-size: 12pt; font-family: Lato; } img { display: ; max-width: ; width: ; height: ; } } Affected component: Hardware Asset Management (HAM) – POL Receive import flowAffected areas: Asset Workspace > Import Assets (staging-to-asset association)Condition: Issue occurs when receiving 2+ assets from the same PO line where each asset has a distinct serial number or asset tagWorkaround available: Use serial number or asset tag as the primary identifier for downstream asset matching logic; these values are correctly stamped on each staging row Release<!-- /*NS Branding Styles*/ --> .ns-kb-css-body-editor-container { p { font-size: 12pt; font-family: Lato; color: var(--now-color--text-primary, #000000); } span { font-size: 12pt; font-family: Lato; color: var(--now-color--text-primary, #000000); } h2 { font-size: 24pt; font-family: Lato; color: var(--now-color--text-primary, black); } h3 { font-size: 18pt; font-family: Lato; color: var(--now-color--text-primary, black); } h4 { font-size: 14pt; font-family: Lato; color: var(--now-color--text-primary, black); } a { font-size: 12pt; font-family: Lato; color: var(--now-color--link-primary, #00718F); } a:hover { font-size: 12pt; color: var(--now-color--link-primary, #024F69); } a:target { font-size: 12pt; color: var(--now-color--link-primary, #032D42); } a:visited { font-size: 12pt; color: var(--now-color--link-primary, #00718f); } ul { font-size: 12pt; font-family: Lato; } li { font-size: 12pt; font-family: Lato; } img { display: ; max-width: ; width: ; height: ; } } This is a known product defect being addressed in Hardware Asset Management v16.0.0. PRB2038406 Cause<!-- /*NS Branding Styles*/ --> .ns-kb-css-body-editor-container { p { font-size: 12pt; font-family: Lato; color: var(--now-color--text-primary, #000000); } span { font-size: 12pt; font-family: Lato; color: var(--now-color--text-primary, #000000); } h2 { font-size: 24pt; font-family: Lato; color: var(--now-color--text-primary, black); } h3 { font-size: 18pt; font-family: Lato; color: var(--now-color--text-primary, black); } h4 { font-size: 14pt; font-family: Lato; color: var(--now-color--text-primary, black); } a { font-size: 12pt; font-family: Lato; color: var(--now-color--link-primary, #00718F); } a:hover { font-size: 12pt; color: var(--now-color--link-primary, #024F69); } a:target { font-size: 12pt; color: var(--now-color--link-primary, #032D42); } a:visited { font-size: 12pt; color: var(--now-color--link-primary, #00718f); } ul { font-size: 12pt; font-family: Lato; } li { font-size: 12pt; font-family: Lato; } img { display: ; max-width: ; width: ; height: ; } } During the POL receive write-back process, the system queries for the newly created asset record using only the purchase_line field as a filter, combined with a limit of 1. Since all assets for the same PO line share the same purchase_line value, the database query returns the first asset found in row order on each iteration of the staging-to-asset matching loop. This results in all staging rows receiving the same (incorrect) asset ID reference. Root cause: Asset matching query lacks serial_number and asset_tag filters to distinguish between multiple assets on the same PO line. Resolution<!-- /*NS Branding Styles*/ --> .ns-kb-css-body-editor-container { p { font-size: 12pt; font-family: Lato; color: var(--now-color--text-primary, #000000); } span { font-size: 12pt; font-family: Lato; color: var(--now-color--text-primary, #000000); } h2 { font-size: 24pt; font-family: Lato; color: var(--now-color--text-primary, black); } h3 { font-size: 18pt; font-family: Lato; color: var(--now-color--text-primary, black); } h4 { font-size: 14pt; font-family: Lato; color: var(--now-color--text-primary, black); } a { font-size: 12pt; font-family: Lato; color: var(--now-color--link-primary, #00718F); } a:hover { font-size: 12pt; color: var(--now-color--link-primary, #024F69); } a:target { font-size: 12pt; color: var(--now-color--link-primary, #032D42); } a:visited { font-size: 12pt; color: var(--now-color--link-primary, #00718f); } ul { font-size: 12pt; font-family: Lato; } li { font-size: 12pt; font-family: Lato; } img { display: ; max-width: ; width: ; height: ; } } Until HAM v16.0.0 is available: Use serial number or asset tag as the reliable identifier for downstream asset operations. These fields are correctly populated on each staging row during import, even though the asset_id references may be incorrect. Steps to verify your environment: Navigate to Hardware Asset Workspace > Import AssetsCreate an import record with a stockroom configuredAdd 3+ staging rows for the same PO line, each with a distinct serial number (e.g., SN-001, SN-002, SN-003) and status = "Ready to Receive"Select all rows and click ReceiveAfter the background job completes, inspect the staging rows: If all rows show the same asset_id value, you are experiencing this issueIf each row shows a distinct asset_id, your environment is not affected Temporary workaround: When performing downstream asset processing (such as moving assets to a stockroom or updating asset records post-receive), validate asset identity using the staging row's serial_number or asset_tag fields rather than relying on the asset_id field for multi-asset POL receives. This ensures you are operating on the correct physical asset until the permanent fix is applied.