Qualys Host Detection Integration stopped processing data after an instance upgradeIssue Qualys Host Detection Integration is not updating records as expected on completed integration runs after the instance was upgraded. Symptoms Previously working Qualys integration runs are completing with 0 New Items and 0 Updated Items reported. No errors are present with the integration run records. Facts Plugin and dependencies are up to dateWhen upgrading to a new Family Release, SecOps and Vulnerability Response Plugins are updated to the lowest compatible version Release Any Cause Qualys Integration for Security Operations script include 'Detectionbase', was customized. This caused the script to be skipped during the Qualys Integration for Security Operations plugin upgrade. The missed update led to an error in the ImportSetTransformer process (Qualys Vulnerabilities) at line 524 of the QualysHostImportReportProcessor script include. Resolution Revert the 'Detectionbase' script include to the latest out-of-box (OOB) version: Navigate to the System Definition >> Script IncludesSet your Application Scope to Vulnerability ResponseOpen the Script IncludeNavigate to the 'Versions' tab in the Related ListsRight-click on the latest out-of-box (OOB) versionSelect 'Revert to this version'Rerun the Qualys imports Related Links Detections, remediation tasks, and vulnerable item states