SCTASK/RITM page auto-scrolls/focuses to a read-only List Collector (slushbucket) variable instead of opening at the topIssue <!-- /*NS Branding Styles*/ --> .ns-kb-css-body-editor-container { p { font-size: 12pt; font-family: Lato; color: var(--now-color--text-primary, #000000); } span { font-size: 12pt; font-family: Lato; color: var(--now-color--text-primary, #000000); } h2 { font-size: 24pt; font-family: Lato; color: var(--now-color--text-primary, black); } h3 { font-size: 18pt; font-family: Lato; color: var(--now-color--text-primary, black); } h4 { font-size: 14pt; font-family: Lato; color: var(--now-color--text-primary, black); } a { font-size: 12pt; font-family: Lato; color: var(--now-color--link-primary, #00718F); } a:hover { font-size: 12pt; color: var(--now-color--link-primary, #024F69); } a:target { font-size: 12pt; color: var(--now-color--link-primary, #032D42); } a:visited { font-size: 12pt; color: var(--now-color--link-primary, #00718f); } ul { font-size: 12pt; font-family: Lato; } li { font-size: 12pt; font-family: Lato; } img { display: ; max-width: ; width: ; height: ; } } When opening an SCTASK or RITM that has a List Collector in the related variables, the page automatically focuses/scrolls down to the List Collector field instead of opening at the top of the form. Symptoms<!-- /*NS Branding Styles*/ --> .ns-kb-css-body-editor-container { p { font-size: 12pt; font-family: Lato; color: var(--now-color--text-primary, #000000); } span { font-size: 12pt; font-family: Lato; color: var(--now-color--text-primary, #000000); } h2 { font-size: 24pt; font-family: Lato; color: var(--now-color--text-primary, black); } h3 { font-size: 18pt; font-family: Lato; color: var(--now-color--text-primary, black); } h4 { font-size: 14pt; font-family: Lato; color: var(--now-color--text-primary, black); } a { font-size: 12pt; font-family: Lato; color: var(--now-color--link-primary, #00718F); } a:hover { font-size: 12pt; color: var(--now-color--link-primary, #024F69); } a:target { font-size: 12pt; color: var(--now-color--link-primary, #032D42); } a:visited { font-size: 12pt; color: var(--now-color--link-primary, #00718f); } ul { font-size: 12pt; font-family: Lato; } li { font-size: 12pt; font-family: Lato; } img { display: ; max-width: ; width: ; height: ; } } On opening an SCTASK or RITM, the form jumps so that a List Collector (slushbucket) variable is in view rather than displaying the top of the record. The behavior occurs when the List Collector variable is rendered read-only. Client scripts added on the task form to reset scroll position do not reliably prevent it, because the List Collector populates and triggers the scroll after the page content and client scripts have already loaded. Facts<!-- /*NS Branding Styles*/ --> .ns-kb-css-body-editor-container { p { font-size: 12pt; font-family: Lato; color: var(--now-color--text-primary, #000000); } span { font-size: 12pt; font-family: Lato; color: var(--now-color--text-primary, #000000); } h2 { font-size: 24pt; font-family: Lato; color: var(--now-color--text-primary, black); } h3 { font-size: 18pt; font-family: Lato; color: var(--now-color--text-primary, black); } h4 { font-size: 14pt; font-family: Lato; color: var(--now-color--text-primary, black); } a { font-size: 12pt; font-family: Lato; color: var(--now-color--link-primary, #00718F); } a:hover { font-size: 12pt; color: var(--now-color--link-primary, #024F69); } a:target { font-size: 12pt; color: var(--now-color--link-primary, #032D42); } a:visited { font-size: 12pt; color: var(--now-color--link-primary, #00718f); } ul { font-size: 12pt; font-family: Lato; } li { font-size: 12pt; font-family: Lato; } img { display: ; max-width: ; width: ; height: ; } } The affected variable is a List Collector (slushbucket) shown in the record's related variables. The auto-scroll is driven by accessibility logic that runs when a slushbucket is set to read-only, which calls scrollIntoView on the element. This logic is associated with the slushbucket record-preview-tooltips accessibility feature, controlled by the user preference glide.ui.accessibility.slushbucket.record_preview_tooltips. Release<!-- /*NS Branding Styles*/ --> .ns-kb-css-body-editor-container { p { font-size: 12pt; font-family: Lato; color: var(--now-color--text-primary, #000000); } span { font-size: 12pt; font-family: Lato; color: var(--now-color--text-primary, #000000); } h2 { font-size: 24pt; font-family: Lato; color: var(--now-color--text-primary, black); } h3 { font-size: 18pt; font-family: Lato; color: var(--now-color--text-primary, black); } h4 { font-size: 14pt; font-family: Lato; color: var(--now-color--text-primary, black); } a { font-size: 12pt; font-family: Lato; color: var(--now-color--link-primary, #00718F); } a:hover { font-size: 12pt; color: var(--now-color--link-primary, #024F69); } a:target { font-size: 12pt; color: var(--now-color--link-primary, #032D42); } a:visited { font-size: 12pt; color: var(--now-color--link-primary, #00718f); } ul { font-size: 12pt; font-family: Lato; } li { font-size: 12pt; font-family: Lato; } img { display: ; max-width: ; width: ; height: ; } } no specific release Cause<!-- /*NS Branding Styles*/ --> .ns-kb-css-body-editor-container { p { font-size: 12pt; font-family: Lato; color: var(--now-color--text-primary, #000000); } span { font-size: 12pt; font-family: Lato; color: var(--now-color--text-primary, #000000); } h2 { font-size: 24pt; font-family: Lato; color: var(--now-color--text-primary, black); } h3 { font-size: 18pt; font-family: Lato; color: var(--now-color--text-primary, black); } h4 { font-size: 14pt; font-family: Lato; color: var(--now-color--text-primary, black); } a { font-size: 12pt; font-family: Lato; color: var(--now-color--link-primary, #00718F); } a:hover { font-size: 12pt; color: var(--now-color--link-primary, #024F69); } a:target { font-size: 12pt; color: var(--now-color--link-primary, #032D42); } a:visited { font-size: 12pt; color: var(--now-color--link-primary, #00718f); } ul { font-size: 12pt; font-family: Lato; } li { font-size: 12pt; font-family: Lato; } img { display: ; max-width: ; width: ; height: ; } } The page scroll is not caused by form focus. When a slushbucket (List Collector) variable is set to read-only, additional accessibility logic runs and calls scrollIntoView on that element. This logic supports the slushbucket record-preview-tooltips feature (which improves preview visibility for users who need high zoom or screen magnification), and it brings the read-only List Collector into view on load, scrolling the page away from the top. Resolution<!-- /*NS Branding Styles*/ --> .ns-kb-css-body-editor-container { p { font-size: 12pt; font-family: Lato; color: var(--now-color--text-primary, #000000); } span { font-size: 12pt; font-family: Lato; color: var(--now-color--text-primary, #000000); } h2 { font-size: 24pt; font-family: Lato; color: var(--now-color--text-primary, black); } h3 { font-size: 18pt; font-family: Lato; color: var(--now-color--text-primary, black); } h4 { font-size: 14pt; font-family: Lato; color: var(--now-color--text-primary, black); } a { font-size: 12pt; font-family: Lato; color: var(--now-color--link-primary, #00718F); } a:hover { font-size: 12pt; color: var(--now-color--link-primary, #024F69); } a:target { font-size: 12pt; color: var(--now-color--link-primary, #032D42); } a:visited { font-size: 12pt; color: var(--now-color--link-primary, #00718f); } ul { font-size: 12pt; font-family: Lato; } li { font-size: 12pt; font-family: Lato; } img { display: ; max-width: ; width: ; height: ; } } This behavior is associated with slushbucket accessibility logic. The related problem (PRB1915516) was closed as Won't Fix, so the following configuration workarounds are available rather than a platform patch. Option 1 — Disable the slushbucket record-preview-tooltips preference. Set the user preference glide.ui.accessibility.slushbucket.record_preview_tooltips to false. When this preference is false, the auto-scroll no longer occurs. This preference governs the display of Record Preview tooltips on applicable slushbuckets (an accessibility aid for high zoom / screen magnification), and it can be set globally for all users. Weigh the accessibility impact before disabling it broadly.Option 2 — Override the preference only where the variables are set read-only. In the script that sets the variables to read-only, add a check that overrides the record-preview-tooltips setting so the scroll-into-view is skipped for that page only. This is a more targeted (but less clean) approach that confines the change to the specific form rather than changing the preference for everyone. Note that a simple client script on the task form alone may not be sufficient, because the List Collector populates and triggers the scroll after the page and client scripts have loaded. Both options were tested and stopped the scrolling. Choose Option 1 for a broad, simple change or Option 2 to limit the change to a specific catalog item/task.