Missing outage and availability data in Service Offering WorkspaceDescriptionMissing outage and availability data in Service Offering WorkspaceCauseThere is no data on the indicator source table to be collected. Scheduled job "SPM Data Collection job for PA" timed out, was modified, or collecting a large amount of data. ResolutionInspect the KPI Group [sn_team_perf_kpi_group], and note the KPIs associated with it. In this Case related to Outage and Availability KPI. Go to the KPI record [pa_indicators] Check the Source in Source tab and open the Indicator Source record. Check which table it is getting the data from eg [service_availability] and verify that there is a data in the source table which pass your conditions. Also check the scheduled job "SPM Data Collection job for PA" and check the "Diagnostic Results" tab if any error. It is by default recorded in [pa_job_logs]. If there is a timeout, it can be due to the data being collected is large or it is collecting from multiple days past the current run. In order for this job to work as originally intended, which is on a nightly basis, relative start and relative end should both be 1.