Revert to base system is not choosing the correct version for sys_ui_action_30c9566dc61122740030e173564c1c74DescriptionBuild information:Quebec Patch 7Issue Description:Revert to base system in the Upgrade History is not choosing the correct (latest) version for sys_ui_action_30c9566dc61122740030e173564c1c74 which is included in multiple plugins. In several instances, it chooses the oldest version of the code.Steps to Reproduce Note that the UI Action (sys_ui_action_30c9566dc61122740030e173564c1c74) lives in multiple plugins:com.snc.bestpractice.incident (Best Practice - Incident Resolution Workflow)com.snc.change_management (Change Management - Core)com.snc.change_management.standard_change_catalog (Change Management - Standard Change Catalog)com.snc.incident (Incident) Modify the UI Action in an older release and upgrade your instance to the currently available releaseIn the Upgrade logs locate the skipped entry for this UI ActionAttempt to revert this UI Action to the Base System versionNote that the base version is not distinguishable from the other plugins and the latest base system version is not always selectedWorkaroundNavigate to the UI Action: /sys_ui_action.do?sys_id=30c9566dc61122740030e173564c1c74 Review the available versions for the UI Action via the Versions related list Select the desired version, right click on the version and select revert to this versionRelated Problem: PRB1527824