Serial number is empty for some stacked switches in DiscoveryIssue <!-- /*NS Branding Styles*/ --> .ns-kb-css-body-editor-container { p { font-size: 12pt; font-family: Lato; color: var(--now-color--text-primary, #000000); } span { font-size: 12pt; font-family: Lato; color: var(--now-color--text-primary, #000000); } h2 { font-size: 24pt; font-family: Lato; color: var(--now-color--text-primary, black); } h3 { font-size: 18pt; font-family: Lato; color: var(--now-color--text-primary, black); } h4 { font-size: 14pt; font-family: Lato; color: var(--now-color--text-primary, black); } a { font-size: 12pt; font-family: Lato; color: var(--now-color--link-primary, #00718F); } a:hover { font-size: 12pt; color: var(--now-color--link-primary, #024F69); } a:target { font-size: 12pt; color: var(--now-color--link-primary, #032D42); } a:visited { font-size: 12pt; color: var(--now-color--link-primary, #00718f); } ul { font-size: 12pt; font-family: Lato; } li { font-size: 12pt; font-family: Lato; } img { display: ; max-width: ; width: ; height: ; } } The serial number field on the main CI and the Serial Number related list is empty for some stacked switches discovered via ServiceNow Discovery. When the SNMP Identify pattern library filters the entPhysicalTable OID results, no entry with entPhysicalContainedIn equal to 0 is returned for the root switch, so the serial number is never set. This is caused by a Cisco bug (CSCuy20251) affecting certain N9k devices, where entPhysicalContainedIn returns 1 instead of 0 for the stack root when there is no entry in the table with entPhysicalIndex of 1. Release<!-- /*NS Branding Styles*/ --> .ns-kb-css-body-editor-container { p { font-size: 12pt; font-family: Lato; color: var(--now-color--text-primary, #000000); } span { font-size: 12pt; font-family: Lato; color: var(--now-color--text-primary, #000000); } h2 { font-size: 24pt; font-family: Lato; color: var(--now-color--text-primary, black); } h3 { font-size: 18pt; font-family: Lato; color: var(--now-color--text-primary, black); } h4 { font-size: 14pt; font-family: Lato; color: var(--now-color--text-primary, black); } a { font-size: 12pt; font-family: Lato; color: var(--now-color--link-primary, #00718F); } a:hover { font-size: 12pt; color: var(--now-color--link-primary, #024F69); } a:target { font-size: 12pt; color: var(--now-color--link-primary, #032D42); } a:visited { font-size: 12pt; color: var(--now-color--link-primary, #00718f); } ul { font-size: 12pt; font-family: Lato; } li { font-size: 12pt; font-family: Lato; } img { display: ; max-width: ; width: ; height: ; } } ALL Cause<!-- /*NS Branding Styles*/ --> .ns-kb-css-body-editor-container { p { font-size: 12pt; font-family: Lato; color: var(--now-color--text-primary, #000000); } span { font-size: 12pt; font-family: Lato; color: var(--now-color--text-primary, #000000); } h2 { font-size: 24pt; font-family: Lato; color: var(--now-color--text-primary, black); } h3 { font-size: 18pt; font-family: Lato; color: var(--now-color--text-primary, black); } h4 { font-size: 14pt; font-family: Lato; color: var(--now-color--text-primary, black); } a { font-size: 12pt; font-family: Lato; color: var(--now-color--link-primary, #00718F); } a:hover { font-size: 12pt; color: var(--now-color--link-primary, #024F69); } a:target { font-size: 12pt; color: var(--now-color--link-primary, #032D42); } a:visited { font-size: 12pt; color: var(--now-color--link-primary, #00718f); } ul { font-size: 12pt; font-family: Lato; } li { font-size: 12pt; font-family: Lato; } img { display: ; max-width: ; width: ; height: ; } } By design, the pattern only keeps the serial number for the root switch when entPhysicalContainedIn equals 0. 1. In the Discovery pattern debugger, run the step Get entPhysicalTable if not already been polled under the SNMP Identify pattern library. 2. Check that the results contain records where entPhysicalContainedIn is 0. If all returned records show entPhysicalContainedIn as 1, this confirms the root cause. Example of a result set that confirms the issue: all records have entPhysicalContainedIn set to 1, with no record where entPhysicalContainedIn is 0. 3. When the Stacked Switches library step Filter entPhysicalTable1 for master stack details runs, it cannot find a match because the filtered result set is empty, so the serial number is never populated for the root switch. The Stacked Switches section of the Network Switch pattern does not include a step to set the reference in the cmdb_serial_number record to the stacked switch CI, which results in serial number records being referenced to the primary switch instead of each individual stacked switch member. This leads to inconsistent serial number population across stack members during Discovery runs. 4. Contact Cisco to confirm whether the device is affected by bug CSCuy20251 and to obtain a fix that causes the device to return the correct value for the stack root. When raising the issue with Cisco, provide the device model, software version, and the SNMP query results showing entPhysicalContainedIn returning 1 for the stack root. Resolution<!-- /*NS Branding Styles*/ --> .ns-kb-css-body-editor-container { p { font-size: 12pt; font-family: Lato; color: var(--now-color--text-primary, #000000); } span { font-size: 12pt; font-family: Lato; color: var(--now-color--text-primary, #000000); } h2 { font-size: 24pt; font-family: Lato; color: var(--now-color--text-primary, black); } h3 { font-size: 18pt; font-family: Lato; color: var(--now-color--text-primary, black); } h4 { font-size: 14pt; font-family: Lato; color: var(--now-color--text-primary, black); } a { font-size: 12pt; font-family: Lato; color: var(--now-color--link-primary, #00718F); } a:hover { font-size: 12pt; color: var(--now-color--link-primary, #024F69); } a:target { font-size: 12pt; color: var(--now-color--link-primary, #032D42); } a:visited { font-size: 12pt; color: var(--now-color--link-primary, #00718f); } ul { font-size: 12pt; font-family: Lato; } li { font-size: 12pt; font-family: Lato; } img { display: ; max-width: ; width: ; height: ; } } Serial number is empty for stacked switches in Discovery, KB0778343 Dell stacked switch serial number not populated during Discovery, KB0964626