Reference Icon does not show in Reference View listDescriptionIn a Reference View list, the reference icon does not appear next to new reference field. Steps to Reproduce Navigate to Incident > All.Open an incident record.Check that the location field is on the form. (If it is not, add the field).Right-click on the Location field label and select Configure Dictionary.In the Attributes field, remove tree_picker=true.Click Update.Next to the Location field, click the Lookup using list icon (magnifying glass).Click New.The New record [Reference List view] popup window appears.Click on the Additional actions icon .Select Configure > Form layout.In Create new field, add a new field: Name: u_countryType: ReferenceTable to reference: Location [cnm_location] Click Add.Click Save.Click Close.The New record [Reference List view] popup window appears again. The reference icon should appear next to the new reference field named u_country, but it does not.In the Application Navigator, type cmn_location.list in the Filter navigator text box.Press the enter or return button on your keyboard.Click on the Additional actions icon .Select Configure > Form layout.Add the new reference field named Country(u_country).Click Save.The field does show the reference icon. The issue only appears in Reference List view.WorkaroundThis behaviour is expected and will not be changed. By design the [sys_ref_list] view does not support a reference icon, because its use would lead to open a further popup within a popup, which can not be supported. Related Problem: PRB705195